PAPERS ICREPQ'06.
Palma de Mallorca, 5, 6, 7 April, 2006; ISBN: 84-609-6604-6
201 Review of the islanding phenomenon
problem for connection of renewable energy systems.
Hector Beltran, Francisco Gimeno, Salvador Seguí-Chilet and Jose
M. Torrelo
206 Analytical investigation of induction
motor drive under DC-link voltage ripple in voltage source inverter.
J. Klima
214 Optimization of a wind turbine using
permanent magnet synchronous generator (PMSG).
Jan Vergauwe, André Martinez, Alberto Ribas.
215 An improved technique for the estimation
of local frequency, fundamental component phasor and instantaneous symmetrical
components.
José C. Ferreira, António P. Martins
217 Effects of the circulating sheath currents
in the magnetic field generated by an underground power line.
J.R. Riba Ruiz, X. Alabern Morera
220 Power control of a variable speed
wind turbine driving an DFIG.
D. Aouzellag, K. Ghedamsi, E.M. Berkouk
221 Modelling of clustered distributed
generation for economic requirements.
M. Neubert, G. Balzer
223 The polymer electrolyte membrane fuel
cell as electric energy source, steady state and dynamic behavior
R. A. Costa, J. R. Camacho, S. C. Gu imarães Jr., and C. H. Salerno
226 Cogeneration in electrical microgrids.
I. Zamora, J.I. San Martín, A.J. Mazón, J.J. San Martín,
V. Aperribay, J.Mª. Arrieta
229 Robust converter synchronization
to a weak grid through a DFT-based Method.
António P. Martins, José C. Ferreira
231 The influence of renewables and international
trade on investment decisions in the grid of the future.
S. Cole, D. Van Hertem, L. Meeus, R. Belmans
236 Variable speed turbine based wind
farm including storage system connected to a power grid or islanded.
A. Davigny, B. Robyns
241 Low-cost orientation system for
a concentrating solar collector with static reflector and tracking receiver
V. Martinez, B. Alorda, A. Moia, R. Pujol
242 Sea energy conversion: Problems and
possibilities.
G. Buigues, I. Zamora, A.J. Mazón, V. Valverde, F.J. Pérez
245 FACTS devices in distributed generation.
Melchor Gómez, Oihane Abarrategui, Inmaculada Zamora
248 Multiobjetive H2/H control of a pitch
regulated wind turbine for mechanical load reduction.
Fabien Lescher, Jing Yun Zhao, André Martinez
250 Evaluation of the renewable energy application
in Mediterranean hotels: Case study the Balearic Islansd` hotels.
A. Moiá-Pol, Michalis Karagiorgas, V. Martínez-Moll, R.Pujol,
Carles Riba-Romeva
251 Power quality improvement of wind
turbines using doubly-fed induction machines.
C. Saniter, R. Grune, A. Wood, R. Hanitsch
253 Effect of using external vertical
fins in phase change material modules for domestic hot water tanks.
Albert Castell, Cristian Solé, Marc Medrano, Joan Roca, Daniel García,
Luisa F. Cabeza.
256 Insulator pollution in transmission
lines.
José A. Ramos Hernanz, José J. Campayo Martín, Joseba
Motrico Gogeascoechea, Inmaculada Zamora Belver
257 Prediction of the thermal behaviour
of an office building using TRNSYS with proposal and evaluation of improvement
actions.
R. Pujol-Nadal, V. Martínez-Moll, A. Moià-Pol
262 Effect on power quality of the high
power electric traction (Double domain computer simulation vs. site measurements).
András Dán , Péter Kiss
264 Power market: effects of the imperfect
competition.
Carlos Redondo Gil, Ana M. Alonso Sánchez, Luis A. Esquibel Tomillo,
Álvaro Fernández Suárez.
267 ATP prediction of voltage sag effect
on sensitive loads.
J. Cardona, J. Barros
270 DSP filter design for flexible
alternating current transmission systems.
O. Abarrategui Ranero, M. Gómez Perez, D.M. Larruskain Eskobal
271 Competition at an energy open
market in the EU and its consecuences on the renewable energy segment.
O. Abarrategui Ranero, D.M. Larruskain Eskobal, M. Gómez Perez
273 Using ultracapacitors in photovoltaic
systems. A technical proposal.
José Antonio Domínguez Vázquez, Fernando Martínez
Rodrigo, José Miguel Ruiz, Santiago Lorenzo Matilla
274 Optimum PI controllers of active power
filters for harmonic voltage mitigation in multibus industrial power systems.
Josef Tlustý, Viktor Valouch
276 Interharmonics injected into power
system by a squirrel-cage induction machine in normal and faulty operation
conditions.
Jan Rusek
277 Setting up a grid simulator.
A. Notholt, D. Coll-mayor, A. Engler
279 Speed control of run-of-river variable
speed hydro plants.
J. Fraile-Ardanuy, J.R. Wilhelmi, J. Fraile-Mora, J.I. Pérez, I.
Sarasua
280 Micro-grid powered by photovoltaic
and micro turbine.
Ph. Degobert, S.Kreuawan, X. Guillaud
282 A little plant of reverse osmosis
fed by an isolated electrical system.
A. Pulido, N. Angulo, J. Romero, C. Quintana, M. Morán
285 Comparison of energy potential of
the eucalyptus globulus and the eucalyptus nitens.
S. Pérez, C.J. Renedo, A. Ortiz, M. Mañana, D. Silió,
J. Peredo
287 Power qualiy measurement of MV
distribution system after connection of small power plant Jakusevec.
Mate Lasic, Marko Sporec, Irena Klaric
292 Analysis of state of MV distribution
system before and after connection of small wind farm Ravna1
Toni Dropulic, Mate Lasic, Jandro Simic
293 Technique-economical viability
of repowering of small hydroelectric power plant considering the social
insert and environmental preservation.
Oscar A. Maldonado, Paulo A. Panuncio, Dinara F. Silva, José Luz
Silveira
295 Short-term prediction of the power
generation of wind turbines.
A. Székely, T. Barbarics
296 Power transmission capacity upgrade
for overhead lines.
D.M. Larruskain, I. Zamora, O. Abarrategui, A. Iraolagoitia, M.D. Gutiérrez,
E. Loroño, F. de la Bodega
297 Comparison of the effect of output
filters on the total harmonic distortion of line current in voltage source
line converter - simulation study.
Pasi Peltoniemi, Riku Pöllänen, Markku Niemelä, Juha Pyrhönen
299 Gas based steady state analysis of
parallel-operated three phase self-excited induction generators
A.I. Alolah, M.A. Alkanhal
400 The impact of induction generator
and PWM inverter with energy storage on weak grids.
H. Bludszuweit, J. A. Domínguez, M. García
401 Pre-feasibility study of a grid
connected wind-PV hybrid system with energy storage and power prediction.
Hans Bludszuweit, José Antonio Domínguez, José Luis
Bernal
403 Influence of wind generator in voltage
dips.
E. Belenguer ,N. Aparicio, J.L. Gandía, S. Añó
405 A performance comparision between
brush and brushless doubly fed asynchronous generators for wind power systems.
R. Carlson, H. Voltolini, F. Runcos, P. Kuo-Peng
408 Orthogonal decomposition of currents,
power definitions and energy transmission in three-phase systems treated
in the time domain.
Gorazd tumberger, Botjan Polajer, Matej Toman, Drago Dolinar
410 Field experiences in power quality
problem solving in Spain.
Z. Larrabe, J.M. López, G. Rojas
411 The influence of harmonics from
non-linear loads in the measuring transformers of electrical substations.
Oscar Armando Maldonado Astorga, José Luz Silveira, Julio Carlos
Damato
416 A simplified electrical model of small
PEM fuel cell.
E. Andrea, M. Mañana, A. Ortiz, C. Renedo, L.I. Eguíluz, S.
Pére, F. Delgado
418 Implementation of a voltage sag characterization
based on a DSP platform.
A. Ortiz, M. Mañana, F. Ortiz, C. J. Renedo, F. Delgado, L.I. Eguiluz
426 Study of an ordinary home electrical
consumption in order to make it more energy-efficient.
António Manuel L. Quadros Flores
427 High energy efficiency test system
for induction heating generators.
V. Esteve, J. Jordán, E.J. Dede, E. Sanchis-Kilders, E. Maset
430 Performance analysis of wind resource
assessment programs in complex terrain.
A. Llombart, A. Talayero, A. Mallet, A. Pera, E. Telmo
431 Hysteresis controller based on a circular
error area table applied to a variable speed renewable energy system.
J. F. Sanz, J. Sallán, M.A. Alonso, M. Sanz, J. L. Villa
432 Development of a low-harmonic vector
hysteresis current controller.
J. F. Sanz, J. Sallán, M. Alonso, M. Sanz, J. L. Villa
435 Analysis by finite element method
of the crosstalk errors associated to the geometrical parameters for current
transducers.
F.J. Arcega, J.S. Artal; J. Letosa, A. Usón
439 Proyect and current energy situation
in the Basque Country
E. Zulueta, L. Gutierrez, I. Manero
442 Analysis of the power production of
a wind farm with consumption associated for desaled water for agriculture,
in Gran Canaria.
A. Pulido, N. Angulo, J. Romero, C. Quintana, L. Darias
444 Fault tolerant shunt active power
filter: topology reconfiguration using optimised fault detection algorithm.
H. El Brouji, P. Poure, M.C. Benhabib, S. Saadate
445 Comparative efficiency of switched
reluctance and induction motor drives for slowly varying loads.
P. Andrada, B. Blanqué, J.I. Perat, M. Torrent, E. Martinez, J.A.
Sánchez
447 Legislative tendency to incorporate
renewable energy in the Spanish Electric Power Production Market.
Mabel Gámez, Ricard Bosch
449 Mathematical approach to THD optimisation
in multilevel convertors.
A. Jan Iwaszkiewicz, B. Jacek Perz
452 3D unsteady flow simulation in
an OWC wave converter plant
A. El Marjani, F. Castro, M. Bahaji, B. Filali
455 Optimisation of renewable energy
system.
K. Mitchell, M. Nagrial, J. Rizk
463 A dynamic model based on a network
of magnetically coupled reluctances for asyncrhonous motor fault analysis.
F. Pedrayes, C.H. Rojas, M.F. Cabanas, M.G. Melero, G.A. Orcajo, J.M. Cano
466 A three-phase grid-connected inverter
for photovoltaic applications using fuzzy MPPT.
Jaime Alonso-Martínez, Santiago Arnaltes
469 Energy management of stand-alone power
systems with renewable energy sources.
S. D`Arco, R. Rizzo, D. Coll-Mayor, P. Tricoli
470 Torque fluctuation and critical clearing
time in wind power generation by induction machines.
Luigi Piegari, Renato Rizzo, Debora Coll-Mayor
473 Frontier methodology to fix quality
goals in electrical energy distribution companies.
R. Ramirez, A. Sudrià, A. Sumper, J. Bergas, R. Villafáfila
475 Influence of the power quality instrument
class on the accurate of the PQ measurement.
Manuel Pérez-Donsión, Saniago Álvarez-Lorenzo
480 A future micro-grid implementation
based on renewable distributed resources for a clean green energy production.
F. Marín, A.B. Rey, A. Guerrero, F. de A. Ruz
483 Internalisation of externalities
in the Spanish power generation sector. Impact of the national plan of allocation
of emissions in the cost of generation.
F. Delgado, A. Ortiz, C.J. Renedo, M. Mañana, F. Ortiz, L.I. Eguiluz
485 Preliminary steady state and dynamic
analysis of a microgrid system
A. Madureira, C. Moreira, J. Peças Lopes
488 Optimization of photovoltaic solar
electric power for renewable energy generation and DSM strategies in singular
apartment buildings.
J.C. Sáenz-Díez Muro, J.M. Blanco-Barrero, E. Jiménez-Macías,
M. Pérez de la Parte, J.I. Latorre Biel
490 SolAgua, a non static compound parabolic
concentrator (CPC) for residential and service buildings.
P. Gata Amaral, E. Ribeiro, R. Brites, F. Gaspar
491 AEROSOL - a micro-scale domestic
autonomous solar Photovoltaic and wind power generation unit in an urban
environment.
F.T. Oliveira, E. Ribeiro, P. Ferreira